Salesforce

Use a Scale With Toast

« Go Back

Fields

 
Article Body

Do you have items with prices determined by their weight? Toast uses both the Brecknell 6710U scale and the new CAS PD-II scale to measure the weight of the item and quickly determine the price on your POS screen. 

 

Already have your own deli scale? Toast can scan the barcode labels produced by any scale vendor that follows the GS1 spec for variable measure items (external link). 

 

The features and functionalities described in this article are currently not available to customers in Canada, Ireland, and the UK.

 

In this Article:

 

Set Up Your Scale

There are several types of scales that are supported with Toast POS. Follow the setup instructions for your scale:

 

Then, continue following the steps in this article to configure the weighed items you'll be selling and set up your POS terminals to work with the scales.

 

Back to top

 

Configure Weighed Items

This step must be completed by the Toast Customer Care team for either scale. Please contact your Customer Care team for help with the steps for configuring weighed items.


Back to top
 

Prompt for Quantity

Make sure all items that need to be weighed have Prompt for Quantity enabled. Once this feature is turned on, the POS will automatically read the weight listed on the scale and multiply it by the price per unit when the item is selected.
 

  1. In Toast Web, navigate to Menus Bulk management Advanced properties, and select the item that needs to have this setting enabled.
  2. On the item details page, scroll down to the Properties settings under Advanced Properties.
  3. Select Yes for the Prompt for Quantity setting.
  4. Scroll down to the Weighing settings, and adjust the Tare Weight and Unit of Measure settings accordingly.
  5. Save and publish your changes.

 

Note: If you have many items that need to have Prompt for Quantity enabled, you can also use the Show/Hide dropdown from the Advanced Properties page (Menus Bulk management Advanced properties) to apply this setting to multiple items at once. You can also show Unit of Measure and Tare Weight on Advanced Properties. 


Any menu Item that has been set up using the steps above will automatically require a scale if one is attached. When ringing in an item, select the item button and place the item on the scale. 


The weight will not appear on the Toast device until the scale settles and registers a consistent weight. You'll then select Done on your POS to add the item to the check. 
 

Note: You cannot manually adjust an item's weight or change the cost on the check without editing the price of the item itself in Quick Edit Mode or in Toast Web. 
 

Back to top
 

Use Your Scale with Kiosk

Your scale can also be used while the POS is in Kiosk Mode, allowing guests to purchase weighed items quickly and efficiently.


After selecting an item that has a unit of measure configured for it, a notification will prompt the guest to place their items on the scale and the price will change automatically on the kiosk. Guests can then select Continue to add the item to their cart and proceed with checkout. 
 

Back to top
 

Scale Troubleshooting

Error Message: Units of Measure Don't Match

If the unit of measure on your scale does not match the item's configuration, you'll receive an error message that says "Configure Scale", and describes the unit of measure that should be used for that particular item. 


If this occurs, simply toggle the weight on your scale to match the item's unit of measure 


Back to top
 

Price Not Transferring From Scale to Toast POS

If your terminal is having trouble receiving any information from a scale, follow the steps below:
 

  1. Unplug your scale's USB connection from the Toast device and from power.
  2. Navigate to the device's Android settings.
  3. Open the Apps section of Android settings.
  4. Select the Toast POS app.
  5. Clear defaults.
  6. Power down the Toast device.
  7. After everything is plugged in, turn on the device.
  8. When the prompt to use attached USB by default comes up, make sure that you check the box to Use by default for this USB device,
  9. Select OK.

 

Back to top

 

Error Message: Invalid Data

If you encounter an "Invalid Data" error on your Brecknell Scales, follow these steps to ensure its accurate weighing and smooth operation:

 

  1. Power on your Brecknell Scale.
  2. Hold down on the Hold/Print and Zero/On/Off buttons, until you see CONFG on the screen.
  3. Press the Unit button once. You should see USER on the screen.
  4. Press the Tare button, once. RESET will be on the screen.
  5. Press the Unit button once. You should see Con1 on the screen.
  6. Select, by pressing the Tare button, once. The bUd.rt will be on the screen.
  7. Toggle through each option in this menu by pressing Unit. Options are LyoUt, bUd.rt, oUt.nd, and Bt.Fnt.
  8. Select the LyoUt option by pressing the Tare button. This will give you a series of options you can select.
    1. Once it says SCP02 press tare to select.
      1. It should move back to LyoUt, if it does not go back to this, select the Zero/On/Off button to go back to the Con1 menu options.
  9. The correct settings for each menu option are the following:
    1. LyoUt = SCP02
    2. bUd.rt = 9600
    3. oUt.nd = Prt.Cd
    4. Bt.Fnt = 8n1
  10. When the process is complete, press the Zero/On/Off button 4 times, and it will restart your scale.
    1. From here, you can choose a Unit until it is on the unit you prefer (lbs, oz, kg, etc).

 

Back to top

 

“0____” Appears on the Screen

If your scale isn't weighing accurately, you can easily recalibrate it by following these steps:

 

  1. With the scale turned on, press and hold the HOLD/PRINT and ZERO/ON/OFF buttons at the same time until the display shows CONFG.
  2. Press the UNIT button twice. The display will show CAL.
  3. Press the TARE button to select it.
  4. The screen will briefly flash a number before displaying CAL.ON. Press the TARE button to confirm.
  5. The display will now show ZEro. Press the TARE button one last time.
  6. Your scale is now calibrated and ready to use!

 

Back to top

 

Scale Showing Incorrect Weight Measurement

Brecknell scale

  1. Power on Brecknell scale.
  2. Hold down on the HOLD/PRINT and ZERO/ON/Off buttons until CONFG appears on the screen.
  3. Press UNIT twice.
  4. You will see CAL on the screen.
  5. Press TARE to select.
  6. You will see "No." and a number on the screen, briefly, then you will see CAL.ON
  7. Press TARE to select.
  8. You will see ZEro on screen.
  9. Press UNIT.
  10. You will see LinE on the screen.
  11. Press TARE to select.
  12. Wait for the device to show 0.00.
  13. Press TARE to select. It will show the maximum weight (usually 15 or 30).
  14. Place an item with a known weight, between three and 30lbs, on the scale.
  15. Adjust the digits to match the weight of the item on the scale. UNIT moves the digit up in value, and HOLD moves to the next digit.
  16. When the correct weight is adjusted and shown on the screen, press TARE twice.
  17. After the system resets, remove the item from the scale, and let the scale zero out.
  18. Place something on the scale with a known weight.

 

CAS sscale

  1. Hold down the # key while powering on the scale. Scale should show ECR set, and then the type setting.
  2. Press the LB/OZ or * key to change the type to Type 5.
  3. Press the ZERO key, and the scale should restart.
  4. Power scale off again.
  5. Hold LB/OZ or * key and power back on.
  6. Toggle LB and OZ by pressing the LB/OZ or * key (0.0 = OZ and 0.000 = LB).

 

A small amount of CAS scales will show LB on the faceplate and have a * button, instead of LB/OZ.


casscalefaceplate2.png

The majority of CAS Scales will look like this:

 

casscalefaceplate1.jpg

 

Back to top

 